Fire Alarm System

An automatic fire alarm system is designed to detect the unwanted presence of fire by monitoring environmental changes associated with combustion. In general, a fire alarm system is classified as either automatically actuated, manually actuated, or both. Automatic fire alarm systems are intended to notify the building occupants to evacuate in the event of a fire or other emergency, report the event to an off-premises location in order to summon emergency services, and to prepare the structure and associated systems to control the spread of fire and smoke.

  • [Image: Conventional Fire Alarm System]
    Conventional Fire Alarm System :

    Microprocessor based fire alarm control panel. Available in range of models from 2 to 64 zones. Provided with key switch for all control functions. Individual hooters for all zones apart from common hooter. Additional one potential free contact per zone. Auto dialer can be interfaced with the panel.Smoke Detector, Heat Detector, Photo Thermal Detector, Flame Detector Response indicator, Manual Call Point, Hooter Devices are used in this microprocessor based Conventional panelte.

  • [Image: Addressable Fire Alarm System]
    Addressable Fire Alarm System :

    Speed of detection. Identification of exact location of fire. Easier maintenance. Tolerance to fault in the system wiring. Allows a single pair of wires to be used for connection. Addressable Smoke Detector, Heat Detector, Photo Thermal Detector, Flame Detector, Manual Call Point, Hooter. LCD display indicates exact location of fire. 255 devices can be connected per loop. Loop length can be extended to 5KM.

  • [Image: Wireless Fire Alarm System]
    Wireless Fire Alarm System :

    Address capacity up to 250 wireless devices. The wireless smoke alarm systems are programmable between any number of zones from 1 to 999. The detectors are equipped with an in-built hooter and test button. There is also an inbuilt hooter in the detectors as well as radio emitter. Each emitter is workable with call button ( manual call point ).

  • [Image: Conventional & Addressable Smoke Detector]
    Conventional & Addressable Smoke Detector :

    Conventional detector: Combine Heat & Smoke Detector, Twin LED for 360° Degree viewing, Sensitivity can adjust by programmer. Its operating voltage 24V loop. Diameter : 100 mm; Height : 50 mm. Addressable detector : Compatible with all kinds of conventional fire alarm control panel. Wide range of operating voltages. Unique optical sensing chamber. Built-in microprocessor intelligent software. Two LEDs blink standby, provide 360'' visibility. Remote indicator LED can be connected.

  • [Image: Conventional & Addressable Photo Electric Detector ]
    Conventional & Addressable Photo Electric Detector :

    Photoelectric detectors use infrared light to detect an object or person passing through a beam. Inside the smoke detector there is a light and a sensor, but they are positioned at 90-degree angles to one another. Latching function helps to identify alarm device clearly and quickly. Detector is made of high endurance, solid and colorfast Fire-proof plastic. Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources. Dual LEDs for 360-degree visibility.

  • [Image: Conventional & Addressable Heat Detector]
    Conventional & Addressable Heat Detector :

    2-wire base connection without polarity sensitivity makes installation much easier. Latching function helps to identify alarm device clearly and quickly. Magnetic test feature makes maintenance easy and simple. Detector is made of high endurance, solid and colorfast Fire-proof plastic. Detector has passed strict EMC test, which greatly eliminates fasle alarms caused by interference from nearby sources. Dual LEDs for 360-degree visibility.

  • [Image: Flame Detector]
    Flame Detector :

    Optical Flame Detectors designed to perform in the harshest environmental conditions and connect directly to alarm or automatic fire extinguishing systems. Flame Detectors can respond to a fire condition in typically less than 50 milliseconds and are designed to detect hydrocarbon fires whilst ignoring potential false alarm hazards such as arc welding, nuclear radiation and x-rays.

  • [Image: Gas Leak Detector]
    Gas Leak Detector :

    Gas leak detection is the process of identifying potentially hazardous gas leaks by means of various sensors, with advanced MPU technology ,Low power consumption . Sensitive and able to retune to zero, Alarm point is adjustable 1%-50%LEL, Zero automatic adjust function, quick and convenient.

  • [Image: Manual Call Point]
    Manual Call Point :

    Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised. Waterproof Manual Call Point with isolator are available.

  • [Image: Conventional & Addressable hooter]
    Conventional & Addressable hooter :

    These hooters produces a sound if smoke or heat is detected in any area. Manufactured as per the requisite norms of the industry, our range is widely utilized in fire protection systems.Sound level: 90 to 110db. Alarm volume: > 85DB (measured at a place 3m in front of the hooter/horn)

  • [Image: Standalone Smoke Detector]
    Standalone Smoke Detector :

    Standalone Smoke Detector has dual ionization smoke sensing chamber. The horn output is 85 decibels at 10 ft. It mounted on a bracket which needs no wiring and it runs on a 9V DC battery. Prevent tampering and provides outstanding durability. Temperature operating range shall be between 400 and 1000. A power on indicator shall be a built in light emitting diode which “blinks” once per minute in the standby condition.

  • [Image: Photoelectric Beam Detector]
    Photoelectric Beam Detector :

    Photoelectric Beam Detector is a rugged dual-beam photoelectric detector designed for a wide variety of outdoor and indoor residential, commercial and industrial applications up to 60m (200 ft) outdoor or 180m (600 ft) indoor. Dual-beam design prevents false alarms from flying birds, insects, falling leaves, etc. Concealed alignment: ± 5o vertical / ± 90o horizontal.